Black Box Explains... Baseband, broadband, and carrierband transmissions.

Depending on the environment and how the electrical signal is sent over the cable, coax can be used for three types of transmissions.

Baseband transmissions use the entire communication channel capacity... more/see it nowto transmit a single data signal. Many LANs employ Thin coax for baseband signaling.

Broadband transmissions use different frequencies to carry several analog signals simultaneously. Each signal can for be a different type of information—data, voice, even video. Broadband transmissions over coax employ either one or two cables. With single-cable coax wiring, frequencies are split into individual channels for each station; some channels are allocated for bidirectional communication. Dual-cable coax wiring uses one cable for sending and one cable for receiving data, each with multiple channels. Broadband transmissions are ideal for long distances. Thick coax is often used for broadband transmissions.

Unlike broadband transmissions, carrierband transmissions can only use one information channel. Carrierband is best suited for the horizontal subsystems (subnetworks) in industrial settings. Many LANs use Thin coax for carrierband signaling. collapse


Black Box Explains...Shielded vs. unshielded cable.

The environment determines whether cable should be shielded or unshielded.

Shielding is the sheath surrounding and protecting the cable wires from electromagnetic leakage and interference. Sources of this electromagnetic activity... more/see it now(EMI)—commonly referred to as noise—include elevator motors, fluorescent lights, generators, air conditioners, and photocopiers. To protect data in areas with high EMI, choose a shielded cable.

Foil is the most basic cable shield, but a copper-braid shield provides more protection. Shielding also protects cables from rodent damage. Use a foil-shielded cable in busy office or retail environments. For industrial environments, you might want to choose a copper-braid shield.

For quiet office environments, choose unshielded cable. collapse


Black Box Explains... Standard and ThinNet Ethernet cabling.

The Ethernet standard supports 10-, 100-, and 1000-Mbps speeds. It supports both half- and full-duplex configurations over twisted-pair and fiber cable, as well as half-duplex over coax cable.

However, the Thick... more/see it nowand ThinNet Ethernet standards support only 10-Mbps speeds.

Standard (Thick) Ethernet (10BASE5)
• Uses “Thick” coax cable with N-type connectors for a backbone and a transceiver cable with 15-pin connectors from the transceiver to the network interface card.
• The maximum number of segments is five, but only three can have computers attached. The others are for network extension.
• The maximum length of one segment is 500 meters.
• The maximum total length of all segments is 2500 meters.
• The maximum length of one transceiver cable is 50 meters.
• The minimum distance between transceivers is 2.5 meters.
• No more than 100 transceiver connections per segment are allowed. A repeater counts as a station for both segments.

Thin Ethernet (ThinNet) (10BASE2)
• Uses “Thin” coax cable (RG-58A/U or RG-58C/U).
• The maximum length of one segment is 185 meters.
• The maximum number of segments is five.
• The maximum total length of all segments is 925 meters.
• The minimum distance between T-connectors is 0.5 meters.
• No more than 30 connections per segment are allowed.
• T-connectors must be plugged directly into each device. collapse


Black Box Explains...SCSI-1, SCSI-2, SCSI-3, and SCSI-5.

There are standards…and there are standards applied in real-world applications. This Black Box Explains illustrates how SCSI is interpreted by many SCSI manufacturers. Think of these as common SCSI connector... more/see it nowtypes, not as firm SCSI specifications. Notice, for instance, there’s a SCSI-5, which isn’t listed among the other approved and proposed specifications. However, for advanced SCSI multiport applications, SCSI-5 is often the connector of choice.

SCSI-1
Supports transfer rates up to 5 MBps and seven SCSI devices on an 8-bit bus. The most common connector is the Centronics® 50 or a DB50. A Micro Ribbon 50 is also used for internal connections. SCSI-1 equipment, such as controllers, can also have Burndy 60 or 68 connectors.

SCSI-2
SCSI-2 introduced optional 16- and 32-bit buses called “Wide SCSI.“ Transfer rate is normally 10 MBps but SCSI-2 can go up to 40 MBps with Wide and Fast SCSI. SCSI-2 usually features a Micro D 50-pin connector with thumbclips. It’s also known as Mini 50 or Micro DB50. A Micro Ribbon 60 connector may also be used for internal connections.

SCSI-3
Found in many high-end systems, SCSI-3 commonly uses a Micro D 68-pin connector with thumbscrews. It’s also known as Mini 68. The most common bus width is 16 bits with transfer rates of 20 MBps.

SCSI-5
SCSI-5 is also called a Very High-Density Connector Interface (VHDCI) or 0.8-mm connector. It’s similar to the SCSI-3 MD68 connector in that it has 68 pins, but it has a much smaller footprint. SCSI-5 is designed for SCSI-5, next-generation SCSI connections. Manufacturers are integrating this 0.8-mm design into controller cards. It’s also the connector of choice for advanced SCSI multiport applications. Up to four channels can be accommodated in one card slot. Connections are easier where space is limited. collapse


Black Box Explains...Loose-tube vs. tight-buffered fiber optic cable.

There are two styles of fiber optic cable construction: loose tube and tight buffered. Both contain some type of strengthening member, such as aramid yarn, stainless steel wire strands, or... more/see it noweven gel-filled sleeves. But each is designed for very different environments.

Loose tube cables, the older of the two cable types, are specifically designed for harsh outdoor environments. They protect the fiber core, cladding, and coating by enclosing everything within semi-rigid protective sleeves or tubes. In loose-tube cables that hold more than one optical fiber, each individually sleeved core is bundled loosely within an all-encompassing outer jacket.

Many loose-tube cables also have a water-resistant gel that surrounds the fibers. This gel helps protect them from moisture, so the cables are great for harsh, high-humidity environments where water or condensation can be a problem. The gel-filled tubes can expand and contract with temperature changes, too.

But gel-filled loose-tube cables are not the best choice when cable needs to be submerged or where it’s routed around multiple bends. Excess cable strain can force fibers to emerge from the gel.

Tight-buffered cables, in contrast, are optimized for indoor applications. Because they’re sturdier than loose-tube cables, they’re best suited for moderate-length LAN/WAN connections, long indoor runs, and even direct burial. Tight-buffered cables are also recommended for underwater applications.

Instead of a gel layer or sleeve to protect the fiber core, tight-buffered cables use a two-layer coating. One is plastic; the other is waterproof acrylate. The acrylate coating keeps moisture away from the cable, like the gel-filled sleeves do for loose-tube cables. But this acrylate layer is bound tightly to the plastic fiber layer, so the core is never exposed (as it can be with gel-filled cables) when the cable is bent or compressed underwater.

Tight-buffered cables are also easier to install because there’s no messy gel to clean up and they don’t require a fan-out kit for splicing or termination. You can crimp connectors directly to each fiber.

Want the best of both worlds? Try a hybrid, breakout-style fiber optic cable, which combines tight-buffered cables within a loose-tube housing. collapse



Product Data Sheets (pdf)...Multicolor Fiber Optic Patch Cables


Black Box Explains...10-Gigabit Ethernet.

10-Gigabit Ethernet (10-GbE), ratified in June 2002, is a logical extension of previous Ethernet versions. 10-GbE was designed to make the transition from LANs to Wide Area Networks (WANs) and... more/see it nowMetropolitan Area Networks (MANs). It offers a cost-effective migration for high-performance and long-haul transmissions at up to 40 kilometers. Its most common application now is as a backbone for high-speed LANs, server farms, and campuses.

10-GbE supports existing Ethernet technologies. It uses the same layers (MAC, PHY, and PMD), and the same frame sizes and formats. But the IEEE 802.3ae spec defines two sets of physical interfaces: LAN (LAN PHY) and WAN (WAN PHY). The most notable difference between 10-GbE and previous Ethernets is that 10-GbE operates in full-duplex only and specifies fiber optic media.

At a glance—Gigabit vs. 10-Gigabit Ethernet

Gigabit
• CSMA/CD + full-duplex
• Leveraged Fibre Channel PMDs
• Reused 8B/10B coding
• Optical/copper media
• Support LAN to 5 km
• Carrier extension

10-Gigabit Ethernet
• Full-duplex only
• New optical PMDs
• New coding scheme 64B/66B
• Optical (developing copper)
• Support LAN to 40 km
• Throttle MAC speed for WAN
• Use SONET/SDH as Layer 1 transport

The alphabetical coding for 10-GbE is as follows:
S = 850 nm
L = 1310 nm
E = 1550 nm
X = 8B/10B signal encoding
R = 66B encoding
W = WIS interface (for use with SONET).

10-GbE
10GBASE-SR — Distance: 300 m; Wavelength: 850 nm; Cable: Multimode
10GBASE-SW — Distance: 300 m; Wavelength: 850 nm; Cable: Multimode
10GBASE-LR — Distance: 10 km; Wavelength: 1310 nm; Cable: Single-Mode
10GBASE-LW — Distance: 10 km; Wavelength: 1310 nm; Cable: Single-Mode
10GBASE-LX4 — Distance: Multimode 300 m, Single-Mode 10 km; Wavelength: Multimode 1310 nm, Single-Mode WWDM; Cable: Multimode or Single-Mode
10GBASE-ER — Distance: 40 km; Wavelength: 1550 nm; Cable: Single-Mode
10GBASE-EW — Distance: 40 km; Wavelength: 550 nm; Cable: Single-Mode
10GBASE-CX4* — Distance: 15 m; Wavelength: Cable: 4 x Twinax
10GBASE-T* — Distance: 25–100 m; Wavelength: Cable: Twisted Pair
* Proposed for copper. collapse


Black Box Explains... RJ-48

An RJ-48 plug is often mistaken for RJ-45. On the outside, the two look identical—both are housed in a miniature 8-position jack. The difference is in the pairing of the... more/see it nowwires.

In RJ-48, two of the wires are for transmit, two are for receive, and two are for the drain. The last two wires are reserved for future use.

There are three subsets within RJ-48: RJ-48C, RJ-48X, and RJ-48S.

RJ-48C and RJ-48X are very similar. Both use lines 1, 2, 4, and 5 and connect T1 lines. The RJ-48C is more common. The difference is that RJ-48X connectors have shorting bars.

RJ-48S uses lines 1, 2, 7, and 8. It connects 56K DDS lines. collapse

  • Pdf Drawing... 
  • Multimode, 50-Micron Duplex Fiber Optic Patch Cable PDF Drawing
    PDF Drawing of EFN6023 Series (Version 1)
 
Results 1-10 of 380 1 2 3 4 5 > >> 
Close

Support

Delivering superior technical support is our highest priority. Depending on the products or services we provide for you, please visit your appropriate support area.



 

You have added this item to your cart.

Important message about your cart:

You requested more of "" than the currently available. The quantity has been changed to them maximum quantity available. View your cart.

Print
Black Box 1-800-316-7107 Black Box Network Services