Black Box Explains...Choosing a cabinet.

Understanding cabinet and rack measurements.
The main component of a cabinet is a set of vertical rails with mounting holes to which you attach your equipment or shelves. When you consider... more/see it nowthe width or height of a cabinet, clarify whether the dimensions are inside or outside.

The first measurement you need to know is the width of the rails. The most common size is 19 inches with hole-to-hole centers measuring 18.3 inches. There are also 23-inch and 24-inch cabinets and racks. Most rackmount equipment is made to fit 19-inch rails but can be adapted for wider rails.

After width, the most important specification is the number of rack units, abbreviated as “U.” It’s a measurement of space available to mount equipment. Because cabinet width is standard, the amount of space is what determines how much equipment you can actually install. Remember, this is an internal measurement of usable space and is smaller than an external measure of the cabinet or rack.

One rack unit (1U) is 1.75 inches of usable space and is usually, but not always, measured vertically. So, for example, a rackmount device that’s 2U high takes up 3.5 inches of rack space. A rack that’s 20U high has 35 inches of usable space.

Choosing the right cabinet.
Here’s a quick checklist of features to keep in mind before you choose a cabinet for servers or other network devices:
• High-volume airflow.
• Adjustable rails.
• Rails with M6 square holes.
• Moisture and dust resistance.
• Air filters.
• Front and/or rear accessibility.
• Locking doors.
• Left- or right-hinging doors.
• Power strips and cable organizers.
• Interior lighting.
• Preassembly.
• Availability of optional shelves, fans, and casters.
• Cable management rails, space, and knockouts.
• Extra depth to accommodate newer, deeper servers.

Don’t forget to accessorize.
Even if your cabinet is in a climate-controlled room, you may need to add a fan panel to help keep your equipment from overheating. It’s especially important to have ventilation in an enclosed cabinet.

Rackmount power strips mount either vertically or horizontally. Some have widely spaced outlets to accommodate transformer blocks. Some power strips include surge protection.

Mission-critical equipment should be connected to an uninterruptible power supply (UPS). A UPS keeps your equipment from crashing during a brief blackout or brownout and provides you with enough time to shut down everything properly in a more extended power outage.

For accessories that make cabling easier, just take a look at our many cable management products. We have cable management guides, rackmount raceways, horizontal and vertical organizers, cable managers, cable hangers, and much more. collapse


Black Box Explains...CAT5: When more isn’t always better.

In data communications applications, using products that exceed required capacities is usually not a problem. For example, if a 28.8K modem is required, a 33.6K or 56K model will work... more/see it nowjust fine.

But sometimes, more isn’t better. Take KVM extenders designed to expect CAT5 and only CAT5 cable. You’d expect that Category 3 cable wouldn’t be effective with these products, and you would be right.

But you may also assume that if Category 5 cable works fine, Category 5e, Category 6, and other higher-capacity cables would work even better. Unfortunately, this isn’t the case, and here’s why:

KVM extenders from many manufacturers, including ServSwitch CAT5 KVM Extenders, are designed specifically for the Category 5 specs defined by the TIA/EIA standard. Higher-level cables, such as Category 5e, have different characteristics and specifications. Although differences—specifically twist ratios—might seem small, they can have a negative impact on these extenders, which are expecting a true Category 5 transmission.

So with ServSwitch CAT5 KVM Extenders, you can think big with CAT5—just don’t think bigger. collapse


Black Box Explains...Fiber connectors.

• The ST® connector, which uses a bayonet locking system, is the most common connector.

• The SC connector features a molded body and a push- pull locking system.

• The FDDI... more/see it nowconnector comes with a 2.5-mm free-floating ferrule and a fixed shroud to minimize light loss.

• The MT-RJ connector, a small-form RJ-style connector, features a molded body and uses cleave-and-leave splicing.

• The LC connector, a small-form factor connector, features a ceramic ferrule and looks like a mini SC connector.

• The VF-45™connector is another small-form factor connector. It uses a unique “V-groove“ design.

• The FC connector is a threaded body connector. Secure it by screwing the connector body to the mating threads. Used in high-vibration environments.

• The MTO/MTP connector is a fiber connector that uses high-fiber-count ribbon cable. It’s used in high-density fiber applications.

• The MU connector resembles the larger SC connector. It uses a simple push-pull latching connection and is well suited for high-density applications.
collapse


Black Box Explains...UTP cable and color drift.

UTP cable is often used with video or KVM extenders to extend the reach of a video signal. It’s popular for this application because it’s lightweight, easy to handle, and... more/see it nowinexpensive. But when you transmit video over long stretches of twisted-pair cable, you sometimes run into a phenomenon called color drift or color split.

Color drift shows up as that annoying colored shadow you occasionally see around objects on a video screen. It sometimes happens with UTP cable because the pairs of wire in the cable are twisted at slightly different rates to reduce crosstalk between pairs. Because of these differences between wire pairs, video signals for different colors often travel different distances before they reach the remote receiver. When one color signal arrives behind the others because its wire is longer, you get that red, green, or blue shadow around the objects on your video screen.

UTP cable varies widely by manufacturer, so before installing video extenders, it’s difficult to determine whether or not you’re going to have a color drift problem. You’re more likely to experience color drift with higher grades (CAT5e or CAT6) of cable, on longer cable runs, and on high-resolution screens.

If you experience color drift, there are several possible solutions. You can use a shorter length of cable, switch from CAT5e or CAT6 cable to CAT5 cable, use a lower screen resolution, or use a video skew compensator.

A video skew compensator removes color drift by delaying some color signals to compensate for differences in wire pairs. collapse


Black Box Explains...Fiber optic cable construction.

Fiber optic cable consists of a core, cladding, coating, strengthening fibers, and cable jacket.

Core
This is the physical medium that transports optical data signals from an attached light source to... more/see it nowa receiving device. The core is a single continuous strand of glass or plastic that’s measured (in microns) by the size of its outer diameter. The larger the core, the more light the cable can carry.

All fiber optic cable is sized according to its core’s outer diameter.

The three multimode sizes most commonly available are 50, 62.5, and 100 microns. Single-mode cores are generally less than 9 microns.

Cladding
This is a thin layer that surrounds the fiber core and serves as a boundary that contains the light waves and causes the refraction, enabling data to travel throughout the length of the fiber segment.

Coating
This is a layer of plastic that surrounds the core and cladding to reinforce the fiber core, help absorb shocks, and provide extra protection against excessive cable bends. These buffer coatings are measured in microns (µ) and can range from 250 to 900 microns.

Strengthening fibers
These components help protect the core against crushing forces and excessive tension during installation.

The materials can range from Kevlar® to wire strands to gel-filled sleeves.

Cable jacket
This is the outer layer of any cable. Most fiber optic cables have an orange jacket, although some types can have black or yellow jackets. collapse


Black Box Explains...Why you should consider a UPS.

Downtime is unacceptable and often costly. But it’s impossible to get 99.9% uptime when you plug your hardware into an AC outlet.

Power problems are the most common cause of network... more/see it nowinterruptions. According to an IBM® study, the average system is hit by 120 power disturbances per month.

Have you ever had to reset the clock on your VCR or seen the lights dim for a moment when the refrigerator kicks on? These are common occurrences that are insignificant at home but can cause a shutdown in your network. Many power disturbances are so short they’re invisible to the human eye, but they can make a router lock up or a switch require rebooting. Power problems are actually more common than you may know. For instance:
• 34% of network downtime is because of bad power (IBM study).
• 99% of power problems are brownouts (low voltage) or blackouts (complete outages). Only a UPS protects against those.
• It takes 90.87 seconds for switches in non redundant networks to recover from power interruptions.
• 45% of all data loss is caused by power problems.

For a small fraction of the cost of your networking hardware, you can purchase a UPS that protects your network from blackouts, brownouts (low voltages), and surges—even lightning strikes!

To prevent power disasters before they happen, more than 70% of servers are protected with a UPS. Network managers know that having a server down brings many operations to a halt. Although the loss of a single hub or router may not bring the entire corporation to a standstill, it can result in zero productivity for entire workgroups or remote offices.

How can you tell if your system is suffering from power problems?

See if some of these symptoms are familiar: damaged hardware, numerous service calls, erratic operation, unexplained problems, unreliable data, system slowdown, damaged software, system lockups, and more.

If you’ve experienced some of these problems, you need a UPS. It will keep power flowing, giving you enough time to shut down safely during a power outage. It will also regulate your power, smoothing out dangerous overvoltages and undervoltages, spikes, surges, and impulses that often go unnoticed. These power anomalies can be caused internally by nearby machinery, fluorescent lights, and elevators, as well as externally from nearby transformer problems, lightning strikes, downed power lines, and more.

Data and equipment losses from power problems are preventable. Eliminate system downtime and increase profitability and productivity with a UPS.

When looking for a UPS, consider these steps:

1. List all the equipment you have that needs protection. Remember to include monitors, terminals, hard drives, external modems, and any other equipment in the critical path of potential power or surge sources.

2. Add up the total amperage ratings of your equipment. This information is probably imprinted on the back of each device.

3. Multiply this total amperage figure by the operating voltage (typically 120 VAC in the U.S.) to obtain your total volt/amp (VA) requirement with a safety margin.

4. Select a UPS with a VA capacity at least as high as the amount in Step 3. To accommodate for future expansion, it’s wise to order a device with an even larger VA rating.

5. If you have questions about which UPS is right for you, contact Tech Support. collapse


Black Box Explains...Ceramic and composite ferrules.

Cables manufactured with ceramic ferrules are ideal for mission-critical applications or connections that are changed frequently. These cables are high quality and typically have a very long life. Ceramic ferrules... more/see it noware more precisely molded and fit closer to the fiber than their composite counterparts, which gives them a lower optical loss.

On the other hand, cables with composite ferrules are ideal for less critical applications or connections that won’t be changed frequently. Composite ferrule cables are characterized by low loss, good quality, and long life. collapse


Black Box Explains...Low-profile PCI serial adapters.

Ever notice that newer computers are getting smaller and slimmer? That means regular PCI boards won’t fit into these computers’ low-profile PCI slots. But because miniaturization is the rage in... more/see it nowall matters of technology, it was only a short matter of time before low-profile PCI serial adapters became available—and Black Box has them.

Low-profile cards meet the PCI Special Interest Group (PCI-SIG) Low-Profile PCI specifications, the form-factor definitions for input/output expansion. Low-Profile PCI has two card lengths defined for 32-bit bus cards: MD1 and MD2. MD1 is the smaller of the two, with cards no larger than 4.721 inches long and 2.536 inches high. MD2 cards are a maximum of 6.6 inches long and 2.536 inches high.

BLACK BOX® Low-Profile Serial PCI cards comply with the MD1 low-profile specification and are compatible with the universal bus. Universal bus is a PCI card that can operate in either a 5-V or 3.3-V signaling level system. collapse


Black Box Explains...Category 6.

Category 6 (CAT6)–Class E has a specified frequency of 250 MHz, significantly improved bandwidth capacity over CAT5e, and easily handles Gigabit Ethernet transmissions. In recent years, it has been the... more/see it nowcable of choice for new structured cabling systems. CAT6 supports 1000BASE-T and, depending on the installation, 10GBASE-T (10-GbE).

10-GbE over CAT6 introduces the problem of Alien Crosstalk (ANEXT), the unwanted coupling of signals between adjacent pairs and cables. Because ANEXT in CAT6 10-GbE networks is so dependent on installation practices, TSB-155 qualifies 10-GbE over CAT6 up to 55 meters and requires it to be 100% tested. To mitigate ANEXT in CAT6, it is recommended that you unbundle the cables and increase the separation between the cables.

You can always contact Black Box Tech Support to answer your cabling questions. Our techs can recommend cable testers and steer you in the right direction when you’re installing new cabling. And the advice is FREE! collapse

  • Pdf Drawing... 
  • GigaStation2 Snap Fitting, SC Simplex, Female/Female, Ivory PDF Drawing
    PDF Drawing for FMT325-R3 (Version 1)
 
Results 1-10 of 2453 1 2 3 4 5 > >> 
Close

Support

Delivering superior technical support is our highest priority. Depending on the products or services we provide for you, please visit your appropriate support area.



 

You have added this item to your cart.

Important message about your cart:

You requested more of "" than the currently available. The quantity has been changed to them maximum quantity available. View your cart.

Print
Black Box 1-800-316-7107 Black Box Network Services