Black Box Explains...PC, UPC, and APC fiber connectors.
Fiber optic cables have different types of mechanical connections. The type of connection determines the quality of the fiber optic lightwave transmission. The different types well discuss here are the... more/see it nowflat-surface, Physical Contact (PC), Ultra Physical Contact (UPC), and Angled Physical Contact (APC).
The original fiber connector is a flat-surface connection, or a flat connector. When mated, an air gap naturally forms between the two surfaces from small imperfections in the flat surfaces. The back reflection in flat connectors is about -14 dB or roughly 4%.
As technology progresses, connections improve. The most common connection now is the PC connector. Physical Contact connectors are just thatthe end faces and fibers of two cables actually touch each other when mated.
In the PC connector, the two fibers meet, as they do with the flat connector, but the end faces are polished to be slightly curved or spherical. This eliminates the air gap and forces the fibers into contact. The back reflection is about -40 dB. This connector is used in most applications.
An improvement to the PC is the UPC connector. The end faces are given an extended polishing for a better surface finish. The back reflection is reduced even more to about -55 dB. These connectors are often used in digital, CATV, and telephony systems.
The latest technology is the APC connector. The end faces are still curved but are angled at an industry-standard eight degrees. This maintains a tight connection, and it reduces back reflection to about -70 dB. These connectors are preferred for CATV and analog systems.
PC and UPC connectors have reliable, low insertion losses. But their back reflection depends on the surface finish of the fiber. The finer the fiber grain structure, the lower the back reflection. And when PC and UPC connectors are continually mated and remated, back reflection degrades at a rate of about 4 to 6 dB every 100 matings for a PC connector. APC connector back reflection does not degrade with repeated matings. collapse
Black Box Explains...PC, UPC, and APC fiber connectors.
Fiber optic cables have different types of mechanical connections. The type of connection determines the quality of the fiber optic lightwave transmission. The different types well discuss here are the flat-surface, Physical Contact (PC), Ultra Physical Contact (UPC), and Angled Physical Contact (APC).
The original fiber connector is a flat-surface connection, or a flat connector. When mated, an air gap naturally forms between the two surfaces from small imperfections in the flat surfaces. The back reflection in flat connectors is about -14 dB or roughly 4%.
As technology progresses, connections improve. The most common connection now is the PC connector. Physical Contact connectors are just thatthe end faces and fibers of two cables actually touch each other when mated.
In the PC connector, the two fibers meet, as they do with the flat connector, but the end faces are polished to be slightly curved or spherical. This eliminates the air gap and forces the fibers into contact. The back reflection is about -40 dB. This connector is used in most applications.
An improvement to the PC is the UPC connector. The end faces are given an extended polishing for a better surface finish. The back reflection is reduced even more to about -55 dB. These connectors are often used in digital, CATV, and telephony systems.
The latest technology is the APC connector. The end faces are still curved but are angled at an industry-standard eight degrees. This maintains a tight connection, and it reduces back reflection to about -70 dB. These connectors are preferred for CATV and analog systems.
PC and UPC connectors have reliable, low insertion losses. But their back reflection depends on the surface finish of the fiber. The finer the fiber grain structure, the lower the back reflection. And when PC and UPC connectors are continually mated and remated, back reflection degrades at a rate of about 4 to 6 dB every 100 matings for a PC connector. APC connector back reflection does not degrade with repeated matings.
Black Box Explains...Fiber optic attenuators.
Attenuators are used with single-mode fiber optic devices and cable to filter the strength of the fiber optic signal. Depending on the type of attenuator attached to the devices at... more/see it noweach end of the fiber optic cable, you can diminish the strength of the light signal a variable amount, measured in decibels (dB).
Why would you want to filter the strength of the fiber optic signal? Single-mode fiber is designed to carry a fiber optic signal long distances—as much as 70 kilometers (or 43.4 miles). Fiber devices send this signal with great force to ensure that the signal, and your data, arrive at the other end intact.
But when two fiber devices connected with single-mode fiber cable are close to each other, the signal may be too strong. As a result, the light signal reflects back down the fiber cable. Data can be corrupted and transmissions can be faulty. A signal that is too strong can even damage the attached equipment.
Because its probably not feasible to move your fiber equipment farther apart, the easiest solution is to attach an attenuator to each fiber device. Just as sunglasses filter the strength of sunlight, attenuators filter the strength of the light signal transmitted along single-mode fiber cable. Within the attenuator, theres doping that reduces the strength of the signal passing through the fiber connection and minute air gaps where the two fibers meet. Fiber grooves may also be intentionally misaligned by several microns—but only enough to slow the fiber optic signal to an acceptable rate as it travels down the cable.
Before selecting an attenuator, you need to check the type of adapter on your fiber devices. Attenuators typically fit into any patch panel equipped with FC, SC, or LC adapters that contain either PC or APC contacts. In addition to the type of adapter, you also need to determine the necessary attenuation value, such as 5 or 10 dB. This value varies, depending on the strength of fiber optic signal desired. collapse
Black Box Explains...Fiber optic attenuators.
Attenuators are used with single-mode fiber optic devices and cable to filter the strength of the fiber optic signal. Depending on the type of attenuator attached to the devices at each end of the fiber optic cable, you can diminish the strength of the light signal a variable amount, measured in decibels (dB).
Why would you want to filter the strength of the fiber optic signal? Single-mode fiber is designed to carry a fiber optic signal long distances—as much as 70 kilometers (or 43.4 miles). Fiber devices send this signal with great force to ensure that the signal, and your data, arrive at the other end intact.
But when two fiber devices connected with single-mode fiber cable are close to each other, the signal may be too strong. As a result, the light signal reflects back down the fiber cable. Data can be corrupted and transmissions can be faulty. A signal that is too strong can even damage the attached equipment.
Because its probably not feasible to move your fiber equipment farther apart, the easiest solution is to attach an attenuator to each fiber device. Just as sunglasses filter the strength of sunlight, attenuators filter the strength of the light signal transmitted along single-mode fiber cable. Within the attenuator, theres doping that reduces the strength of the signal passing through the fiber connection and minute air gaps where the two fibers meet. Fiber grooves may also be intentionally misaligned by several microns—but only enough to slow the fiber optic signal to an acceptable rate as it travels down the cable.
Before selecting an attenuator, you need to check the type of adapter on your fiber devices. Attenuators typically fit into any patch panel equipped with FC, SC, or LC adapters that contain either PC or APC contacts. In addition to the type of adapter, you also need to determine the necessary attenuation value, such as 5 or 10 dB. This value varies, depending on the strength of fiber optic signal desired.
- Pdf Drawing...
-
Fiber Wall Cabinet, Open-Style, Unloaded (Accepts 4 Adapter Panels) PDF Drawing
PDF Drawing for the JPM401A-R2
- Pdf Drawing...
-
Rackmount Fiber Panel, 1U (Loaded with (24) Single-Mode/Multimode Connectors, LC, 12 Duplex) PDF Dra
PDF Drawing for the JPM380A
- Pdf Drawing...
-
HD Adapter Panel, with (8) Duplex MT-RJ Pairs, PDF Drawing
PDF Drawing for the JPM416A-R2
- Pdf Drawing...
-
Fiber Wall Cabinet, Unloaded, Lock-Style 24-Port (Accepts 4 Adapter Panels) PDF Drawing
PDF Drawing for the JPM402A-R2
- Manual...
-
NEMA-4 Rated Fiber Optic Wallmount Enclosure (with 2 Adapter Panels) User Manual
User Manual for the JPM4001A-R2 (Version 2)
- Pdf Drawing...
-
Rackmount Fiber Panel, 1U (Loaded with (24) Single-Mode/Multimode Connectors, LC, 24 Duplex) PDF Dra
PDF Drawing for the JPM385A
- Pdf Drawing...
-
Standard Adapter Panel, with (6) Duplex MT-RJ Pairs, PDF Drawing
PDF Drawing for the JPM409A-R2
Black Box Explains...NEMA ratings for enclosures.
The National Electrical Manufacturers Association (NEMA) issues guidelines and ratings for an enclosure’s level of protection against contaminants that might come in contact with its enclosed equipment.
There are many numerical... more/see it nowNEMA designations; we’ll discuss NEMA enclosures relevant to our on-line catalog: NEMA 3, NEMA 3R, NEMA 4, NEMA 4X, and NEMA 12.
NEMA 3 enclosures, designed for both indoor and outdoor use, provide protection against falling dirt, windblown dust, rain, sleet, and snow, as well as ice formation.
The NEMA 3R rating is identical to NEMA 3 except that it doesn’t specify protection against windblown dust.
NEMA 4 and 4X enclosures, also designed for indoor and outdoor use, protect against windblown dust and rain, splashing and hose-directed water, and ice formation. NEMA 4X goes further than NEMA 4, specifying that the enclosure will also protect against corrosion caused by the elements.
NEMA 12 enclosures are constructed for indoor use only and are designed to provide protection against falling dirt, circulating dust, lint, fibers, and dripping or splashing noncorrosive liquids. Protection against oil and coolant seepage is also a prerequisite for NEMA 12 designation. collapse
Black Box Explains...NEMA ratings for enclosures.
The National Electrical Manufacturers Association (NEMA) issues guidelines and ratings for an enclosure’s level of protection against contaminants that might come in contact with its enclosed equipment.
There are many numerical NEMA designations; we’ll discuss NEMA enclosures relevant to our on-line catalog: NEMA 3, NEMA 3R, NEMA 4, NEMA 4X, and NEMA 12.
NEMA 3 enclosures, designed for both indoor and outdoor use, provide protection against falling dirt, windblown dust, rain, sleet, and snow, as well as ice formation.
The NEMA 3R rating is identical to NEMA 3 except that it doesn’t specify protection against windblown dust.
NEMA 4 and 4X enclosures, also designed for indoor and outdoor use, protect against windblown dust and rain, splashing and hose-directed water, and ice formation. NEMA 4X goes further than NEMA 4, specifying that the enclosure will also protect against corrosion caused by the elements.
NEMA 12 enclosures are constructed for indoor use only and are designed to provide protection against falling dirt, circulating dust, lint, fibers, and dripping or splashing noncorrosive liquids. Protection against oil and coolant seepage is also a prerequisite for NEMA 12 designation.