Loading


Categories (x) > Cables > Copper Patch Cables (x)

Results 51-60 of 104 << < 6 7 8 9 10 > >> 
  • Pdf Drawing... 
  • GigaBase 350 CAT5e Patch Cable with Snagless Boots (Purple) PDF Drawing
    PDF Drawing for the EVNSL88 series.
 

Product Data Sheets (pdf)...CAT5/CAT5e Shielded and Unshielded Cables

  • Pdf Drawing... 
  • TAA GigaTrue%XAE 3 CAT6A 650-MHz Patch Cable (F/UTP, Slimline, Lockable, Blue) PDF Drawing
    PDF Drawing for the C6APC80S-BL-03, C6APC80S-BL-05, C6APC80S-BL-07, C6APC80S-BL-10, C6APC80S-BL-15, & C6APC80S-BL-20 (Version 1)
 
  • Pdf Drawing... 
  • GigaTrue CAT6 Channel 550-MHz Patch Cable (UTP) with Snagless Boots (Green) PDF Drawing
    PDF Drawing of the EVNSL642 Series
 
  • Pdf Drawing... 
  • GigaTrue%XAE CAT6 Component 550-MHz Patch Cable with Molded Boots (Black) PDF Drawing
    PDF Drawing for the EVNSL677-0003, EVNSL677-0005, EVNSL677-0006, EVNSL677-0007, EVNSL677-0010, EVNSL677-0015, and EVNSL677-0020
 

Product Data Sheets (pdf)...CAT6 400-MHz, Shielded, Solid Backbone Cable

  • Brochure... 
  • Giga 3-Series Cable Brochure
    Get premium performance and lock ability%X97no need to buy new cables. (1)
 
  • Pdf Drawing... 
  • GigaTrue CAT6 Channel 550-MHz Patch Cable (UTP) with Snagless Boots (Orange) PDF Drawing
    PDF Drawing of the EVNSL649 Series
 

Black Box Explains…Component vs. channel testing.

When using a Category 6 system, the full specification includes the testing of each part individually and in an end-to-end-channel. Because CAT6 is an open standard, products from different vendors... more/see it nowshould work together.

Channel testing includes patch cable, bulk cable, jacks, patch panels, etc. These tests cover a number of measurements, including: attenuation, NEXT, PS-NEXT, EL-FEXT, ACR, PS-ACR, EL-FEXT, PS-ELFEXT, and Return Loss. Products that are tested together should work together as specified. In theory, products from all manufacturers are interchangeable. But, if products from different manufacturers are inserted in a channel, end-to-end CAT6 performance may be compromised.

Component testing, on the other hand, is much stricter even though only two characteristics are measured: crosstalk and return loss. Although all CAT6 products should be interchangeable, products labeled as component are guaranteed to perform to a CAT6 level in a channel with products from different manufacturers.

For more information on cable, channel, and component specs, see below.

Buyer’s Guide: CAT5e vs. CAT6 Cable

Standard — CAT5e: TIA-568-B.2; CAT6: TIA-568-B.2-1

Frequency — CAT5e: 100 MHz; CAT6: 250 MHz

Attenuation (maximum at 100 MHz) —
Cable: CAT5e: 22 dB; CAT6: 19.8 dB
Connector: CAT5e: 0.4 dB; CAT6: 0.2 dB
Channel: CAT5e: 24.0 dB; CAT6: 21.3 dB

NEXT (minimum at 100 MHz) —
Cable: CAT5e: 35.3 dB; CAT6: 44.3 dB
Connector: CAT5e: 43.0 dB; CAT6: 54.0 dB
Channel: CAT5e: 30.1 dB; CAT6: 39.9 dB

PS-NEXT (minimum at 100 MHz) — 32.3 dB 42.3 dB

EL-FEXT (minimum at 100 MHz) —
Cable: CAT5e: 23.8 dB; CAT6: 27.8 dB
Connector: CAT5e: 35.1 dB; CAT6: 43.1 dB
Channel: CAT5e: 17.4 dB; CAT6: 23.3 dB

PS-ELFEXT (minimum at 100 MHz) — CAT5e: 20.8 dB; CAT6: 24.8 dB

Return Loss (minimum at 100 MHz) —
Cable: CAT5e: 20.1 dB; CAT6: 20.1 dB
Connector: CAT5e: 20.0 dB: CAT6: 24.0 dB
Channel: CAT5e: 10.0 dB; CAT6: 12.0 dB

Characteristic Impedance — Both: 100 ohms ± 15%

Delay Skew (maximum per 100 m) — Both: 45 ns

NOTE: In Attenuation testing, the lower the number, the better. In NEXT, EL-FEXT, and Return Loss testing, the higher the number, the better. collapse

  • Pdf Drawing... 
  • GigaTrue CAT6 Channel Patch Cable with Basic Connectors (White) PDF Drawing
    PDF Drawing of the EVNSL630 Series
 
Results 51-60 of 104 << < 6 7 8 9 10 > >> 
Close

Support

Delivering superior technical support is our highest priority. Depending on the products or services we provide for you, please visit your appropriate support area.



 
Print
Black Box 1-877-877-2269 Black Box Network Services