Product Data Sheets (pdf)...GigaBase CAT5e Channel Solution

  • Specification Sheet... 
  • GigaTrue 550 CAT6, 550-MHz Stranded Bulk Cable, 4-Pair, PVC, 24 AWG, Pink, 1000-ft. (304.8-m)
 
  • Pdf Drawing... 
  • CAT5e 100-MHz Shielded, Stranded Bulk PVC Cable (FTP), Yellow, PDF drawing
    PDF Drawing for EVNSL0172YL-1000 (v1)
 
  • Specification Sheet... 
  • CAT6 400-MHz Shielded Solid Bulk Cable (F/UTP) (Plenum, Yellow) Spec Sheet
    Specification Sheet for EVNSL0614A-1000
 
  • Pdf Drawing... 
  • GigaTrue%XAE 550 CAT6, 550-MHz Solid Bulk Cable (4-Pair, PVC, Gray) PDF Drawing
    PDF Drawing for the EYN876A-PB-1000 (1)
 
  • Specification Sheet... 
  • CAT5e Shielded 350-MHz Solid Bulk Cable (STP) (24 AWG, 4-Pair, PVC, Orange) Spec Sheet
    Specification Sheet for the EVNSL0510A-1000
 
  • Specification Sheet... 
  • GigaBase 350 CAT5e, 350-MHz Stranded Bulk Cable, Gray, 1000-feet (304.8-m)
 
  • Pdf Drawing... 
  • CAT5e 100-MHz Shielded, Stranded Bulk PVC Cable (FTP), Gray, PDF Drawing
    PDF Drawing for the EVNSL0172GY-1000 (Version 1)
 

Black Box Explains...Cable termination.


Carefully remove the jacketing from the cable and expose one inch of the insulated wire conductors. Do not remove any insulation from the conductors. When the... more/see it nowRJ-45 connector is crimped, the contacts inside will pierce the conductor insulation.


Untwist the wires to within 1/8" of the jacket. Arrange the wires according to the cable spec (568B in this case). Flatten and align the wires. Make one straight cut across all the conductors, removing approximately 1/2" to ensure the ends are of equal length.


Slide the wires into a connector. The cable jacket should extend into the connector about 1/4" for strain relief. Orient the wires so connector Pin 1 aligns with cable Pin 1, etc. Hold the connector in front of you. With the locking tab down, Pin 1 is on the far left.


Insert the connector into a crimp tool. Make sure you’re using the proper die. Firmly squeeze the handles. They’ll lock in a ratcheting action. A final click indicates the connector is firmly latched.


Check your work using a continuity tester or cable certifier rated for the cable standard you’re installing. Your tester should be able to check for shorts, opens, or miswires.


collapse

  • Specification Sheet... 
  • CAT6 400-MHz Shielded Solid Bulk Cable (F/UTP) (Plenum, Violet) Spec Sheet
    Specification Sheet for EVNSL0619A-1000
 
Results 51-60 of 137 << < 6 7 8 9 10 > >> 
Close

Support

Delivering superior technical support is our highest priority. Depending on the products or services we provide for you, please visit your appropriate support area.



 
Print
Black Box 1-877-877-2269 Black Box Network Services