Categories (x) > Cables > Copper Bulk Cables > CAT6 Bulk (x)

Results 11-20 of 28 < 1 2 3 > 
  • Pdf Drawing... 
  • GigaTrue 550 CAT6, 550-MHz Solid Bulk Cable (Plenum, Orange) PDF Drawing
    PDF Drawing for the EYN867A-PB-1000 (1)
 
  • Specification Sheet... 
  • CAT5e Shielded 350-MHz Solid Bulk Cable (STP) (24 AWG, 4-Pair, PVC, Black) Spec Sheet
    Spec Sheet for SP515A-R2 (1)
 
  • Pdf Drawing... 
  • GigaTrue 550 CAT6, 550-MHz Solid Bulk Cable (PVC, Blue) PDF Drawing
    PDF Drawing for the EYN870A-PB-1000 (1)
 

Black Box Explains...Cable termination.


Carefully remove the jacketing from the cable and expose one inch of the insulated wire conductors. Do not remove any insulation from the conductors. When the... more/see it nowRJ-45 connector is crimped, the contacts inside will pierce the conductor insulation.


Untwist the wires to within 1/8" of the jacket. Arrange the wires according to the cable spec (568B in this case). Flatten and align the wires. Make one straight cut across all the conductors, removing approximately 1/2" to ensure the ends are of equal length.


Slide the wires into a connector. The cable jacket should extend into the connector about 1/4" for strain relief. Orient the wires so connector Pin 1 aligns with cable Pin 1, etc. Hold the connector in front of you. With the locking tab down, Pin 1 is on the far left.


Insert the connector into a crimp tool. Make sure you’re using the proper die. Firmly squeeze the handles. They’ll lock in a ratcheting action. A final click indicates the connector is firmly latched.


Check your work using a continuity tester or cable certifier rated for the cable standard you’re installing. Your tester should be able to check for shorts, opens, or miswires.


collapse

  • Pdf Drawing... 
  • GigaTrue 550 CAT6, 550-MHz Solid Bulk Cable (4-Pair, PVC, White) PDF Drawing
    PDF Drawing for the EYN874A-PB-1000 (1)
 

Product Data Sheets (pdf)...GigaTrue CAT6 Channel Solution

  • Pdf Drawing... 
  • GigaTrue 550 CAT6, 550-MHz Solid Bulk Cable (4-Pair, PVC, Green) PDF Drawing
    PDF Drawing for the EYN878A-PB-1000 (1)
 

  • Video...Counterfeit Cable

    Watch this informative, 3-minute video to learn how to identify counterfeit cable. Andy Schmeltzer, the "Cable Guy" at Black Box, explains what to look for when you purchase cable. Some... more/see it nowtip-offs that a cable may be non-compliant or counterfeit can include a price that seems too good to be true, specs or lack thereof, a lighter weight than expected, and more. collapse


Black Box Explains...Solid vs. stranded cable.

Solid-conductor cable is designed for backbone and horizontal cable runs. Use it for runs between two wiring closets or from the wiring closet to a wallplate. Solid cable shouldn’t be... more/see it nowbent, flexed, or twisted repeatedly. Its attenuation is lower than that of stranded-conductor cable.

Stranded cable is for use in shorter runs between network interface cards (NICs) and wallplates or between concentrators and patch panels, hubs, and other rackmounted equipment. Stranded-conductor cable is much more flexible than solid-core cable. However, attenuation is higher in stranded-conductor cable, so the total length of stranded cable in your system should be kept to a minimum to reduce signal degradation. collapse

Results 11-20 of 28 < 1 2 3 > 

Support

Delivering superior technical support is our highest priority. Depending on the products or services we provide for you, please visit your appropriate support area.



 
Print
Black Box 1-877-877-2269
Black Box Network Services