  • Video...Advanced Cooling for Data Centers

    Learn about today’s biggest data center challenges and find out how to cut cooling and power costs by up to 50%. This presentation discusses current options for data center cooling... more/see it nowand how passive liquid cooling installs easily with no downtime, is scalable, and saves on energy bills and space requirements. collapse

  • Manual... 
  • Action Organizer Manual
    Manual forRMT920A, RMT928A and RMT930A (Version 1)
 
  • Manual... 
  • AlertWerks II Dry-Contact Sensor Manual
    Manual for the EME1K1-015, EME1K1-060, and EME1K1-100 (Version 1)
 

Product Data Sheets (pdf)...APC Air Distribution Unit   APC NetworkAIR 1000


Black Box Explains...Choosing a cabinet.

Understanding cabinet and rack measurements.
The main component of a cabinet is a set of vertical rails with mounting holes to which you attach your equipment or shelves. When you consider... more/see it nowthe width or height of a cabinet, clarify whether the dimensions are inside or outside.

The first measurement you need to know is the width of the rails. The most common size is 19 inches with hole-to-hole centers measuring 18.3 inches. There are also 23-inch and 24-inch cabinets and racks. Most rackmount equipment is made to fit 19-inch rails but can be adapted for wider rails.

After width, the most important specification is the number of rack units, abbreviated as “U.” It’s a measurement of space available to mount equipment. Because cabinet width is standard, the amount of space is what determines how much equipment you can actually install. Remember, this is an internal measurement of usable space and is smaller than an external measure of the cabinet or rack.

One rack unit (1U) is 1.75 inches of usable space and is usually, but not always, measured vertically. So, for example, a rackmount device that’s 2U high takes up 3.5 inches of rack space. A rack that’s 20U high has 35 inches of usable space.

Choosing the right cabinet.
Here’s a quick checklist of features to keep in mind before you choose a cabinet for servers or other network devices:
• High-volume airflow.
• Adjustable rails.
• Rails with M6 square holes.
• Moisture and dust resistance.
• Air filters.
• Front and/or rear accessibility.
• Locking doors.
• Left- or right-hinging doors.
• Power strips and cable organizers.
• Interior lighting.
• Preassembly.
• Availability of optional shelves, fans, and casters.
• Cable management rails, space, and knockouts.
• Extra depth to accommodate newer, deeper servers.

Don’t forget to accessorize.
Even if your cabinet is in a climate-controlled room, you may need to add a fan panel to help keep your equipment from overheating. It’s especially important to have ventilation in an enclosed cabinet.

Rackmount power strips mount either vertically or horizontally. Some have widely spaced outlets to accommodate transformer blocks. Some power strips include surge protection.

Mission-critical equipment should be connected to an uninterruptible power supply (UPS). A UPS keeps your equipment from crashing during a brief blackout or brownout and provides you with enough time to shut down everything properly in a more extended power outage.

For accessories that make cabling easier, just take a look at our many cable management products. We have cable management guides, rackmount raceways, horizontal and vertical organizers, cable managers, cable hangers, and much more. collapse

  • Manual... 
  • Pro Series Wallmount Cabinet User Manual
    User Manual for the RM4001A. RM4002A, RM4003A, RM4004A, RM4005A, & RM4007A (Version 2)
 

Black Box Explains...Fiber connectors.

• The ST® connector, which uses a bayonet locking system, is the most common connector.

• The SC connector features a molded body and a push- pull locking system.

• The FDDI... more/see it nowconnector comes with a 2.5-mm free-floating ferrule and a fixed shroud to minimize light loss.

• The MT-RJ connector, a small-form RJ-style connector, features a molded body and uses cleave-and-leave splicing.

• The LC connector, a small-form factor connector, features a ceramic ferrule and looks like a mini SC connector.

• The VF-45™connector is another small-form factor connector. It uses a unique “V-groove“ design.

• The FC connector is a threaded body connector. Secure it by screwing the connector body to the mating threads. Used in high-vibration environments.

• The MTO/MTP connector is a fiber connector that uses high-fiber-count ribbon cable. It’s used in high-density fiber applications.

• The MU connector resembles the larger SC connector. It uses a simple push-pull latching connection and is well suited for high-density applications.
collapse

  • Video...QuietCab

    QuietCab cabinets are acoustic IT enclosures that are perfect for applications where space, noise, and appearance are a concern. Their attractive, furniture-like design fits right into areas like offices, conference... more/see it nowrooms, medical practices, schools, and retail establishments. An acoustic foam lining reduces audible server noise by about 15 dB, and integrated fan panels ensure that the cabinets keep your equipment cool. collapse


  • Manual... 
  • Elite Server-Mount Cabinet Heavy-Duty Solid Shelf User Manual
    User Manual for the RM590-R2 and RM591-R2 (Version 2)
 