Fiber optic cable construction and types.
Multimode vs. single-mode
Multimode cable has a large-diameter core and multiple pathways of light. It is most commonly available in two core sizes: 50-micron and 62.5-micron.
Multimode fiber optic cable can... more/see it nowbe used for most general data and voice fiber applications such as adding segments to an existing network, and in smaller applications such as alarm systems and bringing fiber to the desktop. Both multimode cable cores use either LED or laser light sources.
Multimode 50-micron cable is recommended for premise applications?(backbone, horizontal, and intrabuilding connections). It should be considered for any new construction and for installations because it provides longer link lengths and/or higher speeds, particularly in the 850-nm wavelength, than 62.5-micron cable does.
Multimode cable commonly has an orange or aqua jacket; single-mode has yellow. Other colors are available for various applications and for identification purposes.
Single-mode cable has a small (8–10-micron) glass core and only one pathway of light. With only a single wavelength of light passing through its core, single-mode cable realigns the light toward the center of the core instead of simply bouncing it off the edge of the core as multimode does.
Single-mode cable provides 50 times more distance than multimode cable does. Consequently, single-mode cable is typically used in high-bandwidth applications and in long-haul network connections spread out over extended areas, including cable television and campus backbone applications. Telcos use it for connections between switching offices. Single-mode cable also provides higher bandwidth, so you can use a pair of single-mode fiber strands full-duplex at more than twice the throughput of multimode fiber.
Construction
Fiber optic cable consists of a core, cladding, coating, buffer strengthening fibers, and cable jacket.
The core is the physical medium that transports optical data signals from an attached light source to a receiving device. It is a single continuous strand of glass or plastic that’s measured (in microns) by the size of its outer diameter.
All fiber optic cable is sized according to its core’s outer diameter. The two multimode sizes most commonly available are 50 and 62.5 microns. Single-mode cores are generally less than 9 microns.
The cladding is a thin layer that surrounds the fiber core and serves as a boundary that contains the light waves and causes the refraction, enabling data to travel throughout the length of the fiber segment.
The coating is a layer of plastic that surrounds the core and cladding to reinforce the fiber core, help absorb shocks, and provide extra protection against excessive cable bends. These coatings are measured in microns (µ); the coating is 250µ and the buffer is 900µ.
Strengthening fibers help protect the core against crushing forces and excessive tension during installation. This material is generally Kevlar® yarn strands within the cable jacket.
The cable jacket is the outer layer of any cable. Most fiber optic cables have an orange jacket, although some types can have black, yellow, aqua or other color jackets. Various colors can be used to designate different applications within a network.
Simplex vs. duplex patch cables
Multimode and single-mode patch cables can be simplex or duplex.
Simplex has one fiber, while duplex zipcord has two fibers joined with a thin web. Simplex (also known as single strand) and duplex zipcord cables are tight-buffered and jacketed, with Kevlar strength members.
Because simplex fiber optic cable consists of only one fiber link, you should use it for applications that only require one-way data transfer. For instance, an interstate trucking scale that sends the weight of the truck to a monitoring station or an oil line monitor that sends data about oil flow to a central location.
Use duplex multimode or single-mode fiber optic cable for applications that require simultaneous, bidirectional data transfer. Workstations, fiber switches and servers, Ethernet switches, backbone ports, and similar hardware require duplex cable.
PVC (riser) vs. plenum-rated
PVC cable (also called riser-rated cable even though not all PVC cable is riser-rated) features an outer polyvinyl chloride jacket that gives off toxic fumes when it burns. It can be used for horizontal and vertical runs, but only if the building features a contained ventilation system. Plenum can replace PVC, but PVC cannot be used in plenum spaces.
“Riser-rated” means that the jacket is fire-resistant. However, it can still give off noxious fumes when overheated. The cable carries an OFNR rating and is not for use in plenums.
Plenum-jacketed cables have FEP, such as Teflon®, which emits less toxic fumes when it burns. A plenum is a space within the building designed for the movement of environmental air. In most office buildings, the space above the ceiling is used for the HVAC air return. If cable goes through that space, it must be “plenum-rated.”
Distribution-style vs. breakout-style
Distribution-style cables have several tight-buffered fibers bundled under the same jacket with Kevlar or fiberglass rod reinforcement. These cables are small in size and are typically used within a building for short, dry conduit runs, in either riser or plenum applications. The fibers can be directly terminated, but because the fibers are not individually reinforced, these cables need to be terminated inside a patch panel, junction box, fiber enclosure, or cabinet.
Breakout-style cables are made of several simplex cables bundled together, making a strong design that is larger than distribution cables. Breakout cables are suitable for riser and plenum applications.
Loose-tube vs. tight-buffered
Both loose-tube and tight-buffered cables contain some type of strengthening member, such as aramid yarn, stainless steel wire strands, or even gel-filled sleeves. But each is designed for very different environments.
Loose-tube cable is specifically designed for harsh outdoor environments. It protects the fiber core, cladding, and coating by enclosing everything within semi-rigid protective sleeves or tubes. Many loose-tube cables also have a water-resistant gel that surrounds the fibers. This gel helps protect them from moisture, so the cables are great for harsh, high-humidity environments where water or condensation can be a problem. The gel-filled tubes can also expand and contract with temperature changes. Gel-filled loose-tube cable is not the best choice for indoor applications.
Tight-buffered cable, in contrast, is optimized for indoor applications. Because it’s sturdier than loose-tube cable, it’s best suited for moderate-length LAN/WAN connections, or long indoor runs. It’s easier to install as well, because there’s no messy gel to clean up and it doesn’t require a fan-out kit for splicing or termination.
Indoor/outdoor cable
Indoor/outdoor cable uses dry-block technology to seal ruptures against moisture seepage and gel-filled buffer tubes to halt moisture migration. Comprised of a ripcord, core binder, a flame-retardant layer, overcoat, aramid yarn, and an outer jacket, it is designed for aerial, duct, tray, and riser applications.
Interlocking armored cable
This fiber cable is jacketed in aluminum interlocking armor so it can be run just about anywhere in a building. Ideal for harsh environments, it is rugged and rodent resistant. No conduit is needed, so it’s a labor- and money-saving alternative to using innerducts for fiber cable runs.
Outside-plant cable is used in direct burials. It delivers optimum performance in extreme conditions and is terminated within 50 feet of a building entrance. It blocks water and is rodent-resistant.
Interlocking armored cable is lightweight and flexible but also extraordinarily strong. It is ideal for out-of-the-way premise links.
Laser-optimized 10-Gigabit cable
Laser-optimized multimode fiber cable assemblies differ from standard multimode cable assemblies because they have graded refractive index profile fiber optic cable in each assembly. This means that the refractive index of the core glass decreases toward the outer cladding, so the paths of light towards the outer edge of the fiber travel quicker than the other paths. This increase in speed equalizes the travel time for both short and long light paths, ensuring accurate information transmission and receipt over much greater distances, up to 300 meters at 10 Gbps.
Laser-optimized multimode fiber cable is ideal for premise networking applications that include long distances. It is usually aqua colored.
collapse
Fiber optic cable construction and types.
Multimode vs. single-mode
Multimode cable has a large-diameter core and multiple pathways of light. It is most commonly available in two core sizes: 50-micron and 62.5-micron.
Multimode fiber optic cable can be used for most general data and voice fiber applications such as adding segments to an existing network, and in smaller applications such as alarm systems and bringing fiber to the desktop. Both multimode cable cores use either LED or laser light sources.
Multimode 50-micron cable is recommended for premise applications?(backbone, horizontal, and intrabuilding connections). It should be considered for any new construction and for installations because it provides longer link lengths and/or higher speeds, particularly in the 850-nm wavelength, than 62.5-micron cable does.
Multimode cable commonly has an orange or aqua jacket; single-mode has yellow. Other colors are available for various applications and for identification purposes.
Single-mode cable has a small (8–10-micron) glass core and only one pathway of light. With only a single wavelength of light passing through its core, single-mode cable realigns the light toward the center of the core instead of simply bouncing it off the edge of the core as multimode does.
Single-mode cable provides 50 times more distance than multimode cable does. Consequently, single-mode cable is typically used in high-bandwidth applications and in long-haul network connections spread out over extended areas, including cable television and campus backbone applications. Telcos use it for connections between switching offices. Single-mode cable also provides higher bandwidth, so you can use a pair of single-mode fiber strands full-duplex at more than twice the throughput of multimode fiber.
Construction
Fiber optic cable consists of a core, cladding, coating, buffer strengthening fibers, and cable jacket.
The core is the physical medium that transports optical data signals from an attached light source to a receiving device. It is a single continuous strand of glass or plastic that’s measured (in microns) by the size of its outer diameter.
All fiber optic cable is sized according to its core’s outer diameter. The two multimode sizes most commonly available are 50 and 62.5 microns. Single-mode cores are generally less than 9 microns.
The cladding is a thin layer that surrounds the fiber core and serves as a boundary that contains the light waves and causes the refraction, enabling data to travel throughout the length of the fiber segment.
The coating is a layer of plastic that surrounds the core and cladding to reinforce the fiber core, help absorb shocks, and provide extra protection against excessive cable bends. These coatings are measured in microns (µ); the coating is 250µ and the buffer is 900µ.
Strengthening fibers help protect the core against crushing forces and excessive tension during installation. This material is generally Kevlar® yarn strands within the cable jacket.
The cable jacket is the outer layer of any cable. Most fiber optic cables have an orange jacket, although some types can have black, yellow, aqua or other color jackets. Various colors can be used to designate different applications within a network.
Simplex vs. duplex patch cables
Multimode and single-mode patch cables can be simplex or duplex.
Simplex has one fiber, while duplex zipcord has two fibers joined with a thin web. Simplex (also known as single strand) and duplex zipcord cables are tight-buffered and jacketed, with Kevlar strength members.
Because simplex fiber optic cable consists of only one fiber link, you should use it for applications that only require one-way data transfer. For instance, an interstate trucking scale that sends the weight of the truck to a monitoring station or an oil line monitor that sends data about oil flow to a central location.
Use duplex multimode or single-mode fiber optic cable for applications that require simultaneous, bidirectional data transfer. Workstations, fiber switches and servers, Ethernet switches, backbone ports, and similar hardware require duplex cable.
PVC (riser) vs. plenum-rated
PVC cable (also called riser-rated cable even though not all PVC cable is riser-rated) features an outer polyvinyl chloride jacket that gives off toxic fumes when it burns. It can be used for horizontal and vertical runs, but only if the building features a contained ventilation system. Plenum can replace PVC, but PVC cannot be used in plenum spaces.
“Riser-rated” means that the jacket is fire-resistant. However, it can still give off noxious fumes when overheated. The cable carries an OFNR rating and is not for use in plenums.
Plenum-jacketed cables have FEP, such as Teflon®, which emits less toxic fumes when it burns. A plenum is a space within the building designed for the movement of environmental air. In most office buildings, the space above the ceiling is used for the HVAC air return. If cable goes through that space, it must be “plenum-rated.”
Distribution-style vs. breakout-style
Distribution-style cables have several tight-buffered fibers bundled under the same jacket with Kevlar or fiberglass rod reinforcement. These cables are small in size and are typically used within a building for short, dry conduit runs, in either riser or plenum applications. The fibers can be directly terminated, but because the fibers are not individually reinforced, these cables need to be terminated inside a patch panel, junction box, fiber enclosure, or cabinet.
Breakout-style cables are made of several simplex cables bundled together, making a strong design that is larger than distribution cables. Breakout cables are suitable for riser and plenum applications.
Loose-tube vs. tight-buffered
Both loose-tube and tight-buffered cables contain some type of strengthening member, such as aramid yarn, stainless steel wire strands, or even gel-filled sleeves. But each is designed for very different environments.
Loose-tube cable is specifically designed for harsh outdoor environments. It protects the fiber core, cladding, and coating by enclosing everything within semi-rigid protective sleeves or tubes. Many loose-tube cables also have a water-resistant gel that surrounds the fibers. This gel helps protect them from moisture, so the cables are great for harsh, high-humidity environments where water or condensation can be a problem. The gel-filled tubes can also expand and contract with temperature changes. Gel-filled loose-tube cable is not the best choice for indoor applications.
Tight-buffered cable, in contrast, is optimized for indoor applications. Because it’s sturdier than loose-tube cable, it’s best suited for moderate-length LAN/WAN connections, or long indoor runs. It’s easier to install as well, because there’s no messy gel to clean up and it doesn’t require a fan-out kit for splicing or termination.
Indoor/outdoor cable
Indoor/outdoor cable uses dry-block technology to seal ruptures against moisture seepage and gel-filled buffer tubes to halt moisture migration. Comprised of a ripcord, core binder, a flame-retardant layer, overcoat, aramid yarn, and an outer jacket, it is designed for aerial, duct, tray, and riser applications.
Interlocking armored cable
This fiber cable is jacketed in aluminum interlocking armor so it can be run just about anywhere in a building. Ideal for harsh environments, it is rugged and rodent resistant. No conduit is needed, so it’s a labor- and money-saving alternative to using innerducts for fiber cable runs.
Outside-plant cable is used in direct burials. It delivers optimum performance in extreme conditions and is terminated within 50 feet of a building entrance. It blocks water and is rodent-resistant.
Interlocking armored cable is lightweight and flexible but also extraordinarily strong. It is ideal for out-of-the-way premise links.
Laser-optimized 10-Gigabit cable
Laser-optimized multimode fiber cable assemblies differ from standard multimode cable assemblies because they have graded refractive index profile fiber optic cable in each assembly. This means that the refractive index of the core glass decreases toward the outer cladding, so the paths of light towards the outer edge of the fiber travel quicker than the other paths. This increase in speed equalizes the travel time for both short and long light paths, ensuring accurate information transmission and receipt over much greater distances, up to 300 meters at 10 Gbps.
Laser-optimized multimode fiber cable is ideal for premise networking applications that include long distances. It is usually aqua colored.
Product Data Sheets (pdf)...Low-Profile Secure Wallmount Cabinets Low-Profile Side Wallmount Cabinets
- Manual...
-
Elite QuietCab User Manual
Removing Cabinet from Pallet Instructions (Version 1)
Black Box Explains...What to consider when choosing a rack.
Why racks?
There are several things you should consider when choosing a rack.
What kind of equipment will you be putting in it? If you need frequent access to all sides of... more/see it nowthe equipment, an open rack is more convenient than a cabinet. If your equipment needs ventilation, a rack poses no air circulation limitations. And don’t neglect aesthetics. Will customers or clients see your installation? A rack with cable management looks much neater.
Finally, consider security. Because a rack is open, you need to take steps to secure your equipment. Set up your rack in a locked room so prying fingers can’t access your network equipment.
Racks come in various sizes and installation styles. Some are freestanding; some are designed to be wallmounted. Some can be a combination of both styles, sitting on the floor but attaching to the wall for more stability.
Understanding rack measurements.
The main component of a rack is a set of vertical rails with mounting holes to which you attach your equipment or shelves.
The first measurement you need to know is the width between the two rails. It’s commonly given in inches, measured from one mounting hole to the corresponding hole on the opposing rail. The most common rail width is 19"; 23" rails and racks are also available. Most rackmount equipment is designed to fit 19" rails but can be adapted for wider racks.
The next important specification is the number of rack units, which is abbreviated as “U.” This is a measurement of the vertical space available on the rails. Cabinets and racks and rackmount equipment are all measured in rack units. One rack unit (1U) is equal to 1.75" of usable vertical space. So, for example, a device that’s 2U high takes up 3.5" of rack space. A rack that’s 20U high has 35" of usable space.
Because the widths are standard, the amount of vertical space is what determines how much equipment you can actually install. Remember this measurement of usable vertical space is smaller than the external height of the rack.
Getting power to your equipment.
Unless you want to have a tangle of extension cords, you’ll need to get one or more power strips for your rack. Consider which kind would be best for your installation. Rackmount power strips come in versions that mount either vertically or horizontally. Some have outlets that are spaced widely to accommodate transformer blocks—a useful feature if most of your equipment uses bulky power transformers.
Surge protection is another important issue. Some power strips have built-in surge protection; some don’t. With the money you have invested in rackmount equipment, you’ll certainly want to make sure it’s protected.
Any mission-critical equipment should also be connected to an uninterruptible power supply (UPS). A UPS prevents your equipment from crashing during a brief blackout or brownout and allows enough time to shut everything down properly in the event of an extended power outage. Choose a rackmount UPS for the most critical equipment or plug the whole rack into a standalone UPS.
Managing cables.
Your equipment may look very tidy when it’s all mounted. But unless you’re very careful with your cables, you can create a tangle you’ll never be able to unravel.
Plotting your connections in advance helps you to decide the most efficient way to organize the cables. Knowing where the connections are tells you whether it’s better to run cables horizontally or vertically. Most network problems are in the cabling, so if you let your cables get away from you now, you’re sure to pay for it down the road.
There are many cable management accessories that can simplify your racks. collapse
Black Box Explains...What to consider when choosing a rack.
Why racks?
There are several things you should consider when choosing a rack.
What kind of equipment will you be putting in it? If you need frequent access to all sides of the equipment, an open rack is more convenient than a cabinet. If your equipment needs ventilation, a rack poses no air circulation limitations. And don’t neglect aesthetics. Will customers or clients see your installation? A rack with cable management looks much neater.
Finally, consider security. Because a rack is open, you need to take steps to secure your equipment. Set up your rack in a locked room so prying fingers can’t access your network equipment.
Racks come in various sizes and installation styles. Some are freestanding; some are designed to be wallmounted. Some can be a combination of both styles, sitting on the floor but attaching to the wall for more stability.
Understanding rack measurements.
The main component of a rack is a set of vertical rails with mounting holes to which you attach your equipment or shelves.
The first measurement you need to know is the width between the two rails. It’s commonly given in inches, measured from one mounting hole to the corresponding hole on the opposing rail. The most common rail width is 19"; 23" rails and racks are also available. Most rackmount equipment is designed to fit 19" rails but can be adapted for wider racks.
The next important specification is the number of rack units, which is abbreviated as “U.” This is a measurement of the vertical space available on the rails. Cabinets and racks and rackmount equipment are all measured in rack units. One rack unit (1U) is equal to 1.75" of usable vertical space. So, for example, a device that’s 2U high takes up 3.5" of rack space. A rack that’s 20U high has 35" of usable space.
Because the widths are standard, the amount of vertical space is what determines how much equipment you can actually install. Remember this measurement of usable vertical space is smaller than the external height of the rack.
Getting power to your equipment.
Unless you want to have a tangle of extension cords, you’ll need to get one or more power strips for your rack. Consider which kind would be best for your installation. Rackmount power strips come in versions that mount either vertically or horizontally. Some have outlets that are spaced widely to accommodate transformer blocks—a useful feature if most of your equipment uses bulky power transformers.
Surge protection is another important issue. Some power strips have built-in surge protection; some don’t. With the money you have invested in rackmount equipment, you’ll certainly want to make sure it’s protected.
Any mission-critical equipment should also be connected to an uninterruptible power supply (UPS). A UPS prevents your equipment from crashing during a brief blackout or brownout and allows enough time to shut everything down properly in the event of an extended power outage. Choose a rackmount UPS for the most critical equipment or plug the whole rack into a standalone UPS.
Managing cables.
Your equipment may look very tidy when it’s all mounted. But unless you’re very careful with your cables, you can create a tangle you’ll never be able to unravel.
Plotting your connections in advance helps you to decide the most efficient way to organize the cables. Knowing where the connections are tells you whether it’s better to run cables horizontally or vertically. Most network problems are in the cabling, so if you let your cables get away from you now, you’re sure to pay for it down the road.
There are many cable management accessories that can simplify your racks.
- Manual...
-
Flushmount Wall Bracket
Users Manual (8/8/2013)
- Pdf Drawing...
-
NEMA-4 Rated Fiber Optic Wallmount Enclosure PDF Drawing
PDF Drawing for the JPM4000A
Product Data Sheets (pdf)...Pro Series Wallmount Cabinet
Black Box Explains...Fiber connectors.
• The ST® connector, which uses a bayonet locking system, is the most common connector.
• The SC connector features a molded body and a push- pull locking system.
• The FDDI... more/see it nowconnector comes with a 2.5-mm free-floating ferrule and a fixed shroud to minimize light loss.
• The MT-RJ connector, a small-form RJ-style connector, features a molded body and uses cleave-and-leave splicing.
• The LC connector, a small-form factor connector, features a ceramic ferrule and looks like a mini SC connector.
• The VF-45™connector is another small-form factor connector. It uses a unique V-groove design.
• The FC connector is a threaded body connector. Secure it by screwing the connector body to the mating threads. Used in high-vibration environments.
• The MTO/MTP connector is a fiber connector that uses high-fiber-count ribbon cable. Its used in high-density fiber applications.
• The MU connector resembles the larger SC connector. It uses a simple push-pull latching connection and is well suited for high-density applications.
collapse
Black Box Explains...Fiber connectors.
• The ST® connector, which uses a bayonet locking system, is the most common connector.
• The SC connector features a molded body and a push- pull locking system.
• The FDDI connector comes with a 2.5-mm free-floating ferrule and a fixed shroud to minimize light loss.
• The MT-RJ connector, a small-form RJ-style connector, features a molded body and uses cleave-and-leave splicing.
• The LC connector, a small-form factor connector, features a ceramic ferrule and looks like a mini SC connector.
• The VF-45™connector is another small-form factor connector. It uses a unique V-groove design.
• The FC connector is a threaded body connector. Secure it by screwing the connector body to the mating threads. Used in high-vibration environments.
• The MTO/MTP connector is a fiber connector that uses high-fiber-count ribbon cable. Its used in high-density fiber applications.
• The MU connector resembles the larger SC connector. It uses a simple push-pull latching connection and is well suited for high-density applications.